Battery Model | HX6-12 | |||
Capacity (25ºC) |
20HR (5.25V) | 10HR (5.25V) | 1HR (4.80V) | / |
12.0Ah | 11.0Ah | 7.8Ah | / | |
Dimension | Length | Width | Height | Total Height |
151±1mm (5.94inch) | 50±1mm (1.97inch) | 94±1mm (3.70inch) | 100±1mm (3.94inch) | |
Approx. Weight | 1.75kg (3.86lbs) ±5% | |||
Terminal Type | F1/F2 | |||
Internal Resistance (Fully charged, 25ºC) |
Approx. 12mΩ | |||
Capacity affected by temperature (20HR) |
40ºC | 25ºC | 0ºC | -15ºC |
102% | 100% | 85% | 65% | |
Self-discharge | 3 months | 6 months | 12 months | / |
Remaining Capacity: 91% | Remaining Capacity: 82% | Remaining Capacity: 65% | / | |
Nominal Operating Temperature | 25ºC ± 3ºC (77ºF±5ºF) | |||
Operating Temerature Range | Discharge | Charge | Storage | / |
-15ºC~50ºC (5ºF~122ºF) |
-10ºC~50ºC (14ºF~122ºF) |
-20ºC~50ºC (-4ºF~122ºF) |
/ |
|
Charging Voltage (25ºC) | Floating Charging | Cyclic Charging | ||
6.80 to 6.90V Temperature compensation: -9mV/ºC |
7.25 to 7.50V Temperature compensation: -15mV/ºC |
|||
Maximum Charging Current | 3.6A | |||
Maximum Discharge Current | 180A (5 sec.) | |||
Designed Floating Life (20ºC) |
5 years |